产品中心

人钙粘蛋白EGF LAG七经G-型受体2(CELSR2)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK3576
规格: 价格:
48T ¥1960.00
96T ¥2800.00
96T*5 ¥11900.00

Overview

Product name: Human CELSR2(Cadherin EGF LAG Seven Pass G-Type Receptor 2) ELISA Kit
Reactivity: Human
Alternative Names: CDHF10; EGFL2; Flamingo 1; MEGF3; Cadherin family member 10; Epidermal growth factor-like protein 2; Multiple epidermal growth factor-like domains protein 3
Assay Type: Sandwich
Sensitivity: 0.066 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;
Uniprot ID: Q9HCU4
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CELSR2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CELSR2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CELSR2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CELSR2 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
10.00 1.941 1.846
5.00 1.583 1.488
2.50 1.121 1.026
1.25 0.875 0.780
0.63 0.543 0.448
0.32 0.312 0.217
0.16 0.196 0.101
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CELSR2 and the recovery rates were calculated by comparing the measured value to the expected amount of CELSR2 in samples.
Matrix Recovery range Average
serum(n=5) 80-94% 87%
EDTA plasma(n=5) 89-101% 95%
Heparin plasma(n=5) 82-95% 88%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CELSR2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-96% 85-99% 79-93% 89-97%
EDTA plasma(n=5) 85-97% 87-96% 85-96% 85-95%
Heparin plasma(n=5) 86-100% 93-108% 80-101% 87-96%