产品中心

人胰岛素瘤相关抗原2自身抗体酶联免疫吸附检测试剂盒
一键复制产品信息
ELK0858
规格: 价格:
48T ¥1960.00
96T ¥2800.00
96T*5 ¥11900.00

Overview

产品名称: Human IA-2 Ab(Insulinoma associated antigen 2 Autoantibody) ELISA Kit
反应性: Human
别名: IA2 Ab
反应类型: Sandwich
灵敏度: 26.8 U/mL
标准品: 4000 U/mL
检测范围: 62.5-4000 U/mL
样本类型: tissue homogenates, cell lysates and other biological fluids
反应时长: 3.5h
研究领域: Signal transduction
检测原理: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IA-2 Ab. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IA-2 Ab. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IA-2 Ab, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IA-2 Ab in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (U/mL) OD Corrected OD
4000.00 2.054 1.971
2000.00 1.527 1.444
1000.00 1.106 1.023
500.00 0.835 0.752
250.00 0.473 0.390
125.00 0.327 0.244
62.50 0.175 0.092
0.00 0.083 0.000

精密度

板内精密度(测定内的精密度):CV%<8%

三个已知浓度的样品分别在1个酶标板上测试20次,以评估分析板内精密度。

板间精密度(测定板间间精密度):CV%<10%

三个已知浓度的样品分别在3个不同的酶标板上测试40次,以评估分析板间的精密度。

回收率

分别往不同样本中添加已知浓度的IA-2 Ab, 做回收率实验,得出回收率范围和平均回收率
样本类型 回收率范围 平均回收率
血清(n=5) 85-97% 91%
EDTA 血浆(n=5) 91-99% 95%
Heparin 血浆(n=5) 80-92% 86%

线性

将添加有IA-2 Ab的样本分别稀释2倍,4倍,8倍,16倍做回收实验,得出回收率范围
样本类型 1:2 1:4 1:8 1:16
血清(n=5) 88-100% 95-103% 89-97% 85-94%
EDTA 血浆(n=5) 87-103% 97-105% 79-90% 87-96%
Heparin 血浆(n=5) 85-95% 85-96% 93-99% 87-101%