产品中心

人诱饵第三受体(DcR3)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK9819
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human DcR3(Decoy receptor 3) ELISA Kit
Reactivity: Human
Alternative Names: DcR3; Decoy receptor 3; Decoy receptor for Fas ligand; DJ583P15.1.1; M68; M68E; OTTHUMP00000031583; TNF6B_HUMAN; TNFRSF6B; TR6; Tumor necrosis factor receptor superfamily member 6B; Tumor necrosis factor receptor superfamily member 6b decoy; UNQ186/PRO212;
Assay Type: Sandwich
Sensitivity: 25.6 pg/mL
Standard: 4000 pg/mL
Detection Range: 62.5-4000 pg/mL
Sample type: Serum, plasma and other biological fluids
Assay length: 3.5h
Research Area: Cell Biology; Immunology; Cancer
Uniprot ID: O95407
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human DcR3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human DcR3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human DcR3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human DcR3 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
4000.00 2.036 1.951
2000.00 1.593 1.508
1000.00 1.194 1.109
500.00 0.876 0.791
250.00 0.525 0.440
125.00 0.369 0.284
62.50 0.179 0.094
0.00 0.085 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant DcR3 and the recovery rates were calculated by comparing the measured value to the expected amount of DcR3 in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 83-95% 89%
Heparin plasma(n=5) 85-99% 92%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of DcR3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-95% 81-97% 93-102% 89-97%
EDTA plasma(n=5) 85-97% 87-96% 89-103% 82-95%
Heparin plasma(n=5) 87-96% 96-105% 95-103% 85-100%