产品中心

大鼠成肌分化蛋白(MyoD)酶联免疫吸附检测试剂盒
ELK6019
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview 文献

Product name: Rat MyoD(Myogenic Differentiation) ELISA Kit
Reactivity: Rat
Alternative Names: MYOD1; PUM; MYF3; bHLHc1; Myoblast Determination Protein 1; Myogenic Factor 3; Class C basic helix-loop-helix protein 1
Assay Type: Sandwich
Sensitivity: 27 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Metabolic pathway;Cardiovascular biology;Developmental science;Bone metabolism;
Uniprot ID: Q02346
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat MyoD. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat MyoD. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat MyoD, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat MyoD in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
5000.00 1.929 1.837
2500.00 1.577 1.485
1250.00 1.116 1.024
625.00 0.871 0.779
312.50 0.532 0.440
156.25 0.340 0.248
78.13 0.225 0.133
0.00 0.092 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MyoD and the recovery rates were calculated by comparing the measured value to the expected amount of MyoD in samples.
Matrix Recovery range Average
serum(n=5) 94-107% 100%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 95-107% 101%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MyoD and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-94% 97-105% 88-101% 82-96%
EDTA plasma(n=5) 92-104% 82-96% 95-102% 87-98%
Heparin plasma(n=5) 86-97% 83-96% 91-103% 96-105%