产品中心

人成纤维细胞生长因子17(FGF17)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK4432
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human FGF17(Fibroblast Growth Factor 17) ELISA Kit
Reactivity: Human
Alternative Names: FGF 13; FGF 17; FGF-17; FGF13; Fgf17; Fibroblast growth factor 17; HH20
Assay Type: Sandwich
Sensitivity: 2.8 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
Assay length: 3.5h
Research Area: Cytokine;
Uniprot ID: O60258
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human FGF17. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FGF17. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human FGF17, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FGF17 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
500.00 2.266 2.182
250.00 1.786 1.702
125.00 1.384 1.300
62.50 0.752 0.668
31.25 0.487 0.403
15.63 0.387 0.303
7.82 0.235 0.151
0.00 0.084 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FGF17 and the recovery rates were calculated by comparing the measured value to the expected amount of FGF17 in samples.
Matrix Recovery range Average
serum(n=5) 93-107% 100%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 85-99% 92%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FGF17 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-96% 79-95% 95-102%
EDTA plasma(n=5) 85-92% 79-96% 87-103% 90-99%
Heparin plasma(n=5) 88-97% 96-105% 91-103% 89-97%