产品中心

人乳脂球表皮生长因子8(MFGE8)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK3010
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human MFGE8(Milk Fat Globule EGF Factor 8) ELISA Kit
Reactivity: Human
Alternative Names: HMFG; MFGM; SED1; BA46; EDIL1; OAcGD3S; SPAG10; hP47; Medin; Lactadherin; Sperm Associated Antigen 10; Sperm Surface Protein hP47; Milk fat globule-EGF factor 8
Assay Type: Sandwich
Sensitivity: 13.3 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample type: serum, plasma, cell lysates and other biological fluids
Assay length: 3.5h
Research Area: Tumor immunity;
Uniprot ID: Q08431
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MFGE8. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MFGE8. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MFGE8, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MFGE8 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
2000.00 2.105 2.016
1000.00 1.657 1.568
500.00 0.924 0.835
250.00 0.761 0.672
125.00 0.497 0.408
62.50 0.317 0.228
31.25 0.215 0.126
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MFGE8 and the recovery rates were calculated by comparing the measured value to the expected amount of MFGE8 in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 83-98% 90%
Heparin plasma(n=5) 80-95% 87%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MFGE8 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-91% 86-92% 89-96% 91-97%
EDTA plasma(n=5) 81-93% 78-91% 87-98% 95-107%
Heparin plasma(n=5) 82-95% 89-103% 79-91% 85-93%