产品中心

大鼠生长抑素(SST)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK1427
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat SST(Somatostatin) ELISA Kit
Reactivity: Rat
Alternative Names: GHIH; SRIF; SMST; GHRIH; GHRIF; Growth Hormone Releasing Inhibiting Hormone; Somatotropin Release-Inhibiting Factor; Somatostatin-14; Somatostatin-28
Assay Type: Competitive Inhibition
Sensitivity: 2.83 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample type: serum, plasma and other biological fluids
Assay length: 2h
Research Area: Tumor immunity;Endocrinology;Hormone metabolism;
Uniprot ID: P60042
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat SST. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat SST. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat SST in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
500.00 0.235
250.00 0.356
125.00 0.672
62.50 0.897
31.25 1.275
15.63 1.587
7.82 1.835
0.00 2.316

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SST and the recovery rates were calculated by comparing the measured value to the expected amount of SST in samples.
Matrix Recovery range Average
serum(n=5) 87-101% 94%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 84-96% 90%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SST and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-97% 88-102% 85-93% 83-97%
EDTA plasma(n=5) 86-93% 91-105% 87-98% 89-94%
Heparin plasma(n=5) 86-93% 93-101% 86-97% 90-101%
关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭