产品中心

人FMS样酪氨酸激酶3(Flt3)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK1421
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human Flt3(FMS Like Tyrosine Kinase 3) ELISA Kit
Reactivity: Human
Alternative Names: CD135; STK1; FLK2; Fms-Related Tyrosine Kinase 3; Stem Cell Tyrosine Kinase 1; FL Cytokine Receptor; Fetal Liver Kinase-2
Assay Type: Sandwich
Sensitivity: 0.115 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample type: Tissue homogenates, cell lysates and other biological fluids.
Assay length: 3.5h
Research Area: CD & Adhesion molecule;Hematology;
Uniprot ID: P36888
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Flt3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human Flt3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human Flt3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Flt3 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
20.00 1.916 1.829
10.00 1.594 1.507
5.00 1.196 1.109
2.50 0.831 0.744
1.25 0.521 0.434
0.63 0.387 0.300
0.32 0.214 0.127
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant Flt3 and the recovery rates were calculated by comparing the measured value to the expected amount of Flt3 in samples.
Matrix Recovery range Average
serum(n=5) 97-107% 102%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 82-94% 88%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Flt3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-96% 85-99% 79-93% 89-97%
EDTA plasma(n=5) 85-94% 87-101% 89-99% 85-95%
Heparin plasma(n=5) 86-98% 93-106% 89-97% 85-94%